{"product_id":"waterproofing-bluebeam-tool-set","title":"Waterproofing Bluebeam Tool Set","description":"\u003cp\u003eTool set of waterproofing markup tools for plans, sections, and elevations, damp surveys, and inspection and test records. This tool set covers 7 categories with 424 tools, available in black and redline versions. The 61 line tools are native Polyline markups with 61 custom line styles, so the studs, ribs, hachures, waves, and lettering of a membrane, termination, waterstop, DPC, or joint run along any path you draw. Each of the 44 hatch patterns comes as a Polygon tool and an Area tool, and 26 Length tools measure linear items such as sealant joints, expansion joints, membrane terminations, waterstops, hydrophilic strips, termination bars, DPC, cavity trays, and drainage channels. The 211 symbols, tags, notes, test markers, and stamps are native Bluebeam markups, most of them groups; where a symbol carries a code, value, date, or name, it is editable text. Every tool is named for what it marks and that name is also its subject, so placed markups list and count by name in the Markups List.\u003c\/p\u003e\n\u003cp\u003eThe 38 typical details are captioned like a drawing-sheet detail: a split detail bubble with the detail number over a sheet reference, and the title. Each detail places as one group. Its outlines, membrane and sealant lines, leaders, and notes are native Bluebeam markups in full black or red, and the material hatching is one vector snapshot inside the group, in mid grey in the black edition and light red in the redline edition. The notes, the title, and both fields of the bubble are editable text. Notes give millimetres with inches in brackets, and the laps, upstands, falls, and fixings they show are generic values to type over with those of the specified system.\u003c\/p\u003e\n\u003cp\u003eLegend-style tools follow the way waterproofing drawing sets key their plans: hatches for membrane systems 1 to 6 and a membrane system with root barrier, in scope and not in scope (N.I.C.) areas, pedestrian, vehicular, and heavy-duty \/ ramp traffic coatings, existing coating to remain, existing membrane to remain and to be removed, and delamination and spall areas; area, roof \/ deck, and existing drain symbols; membrane termination (horizontal, and vertical types A and B), coating extent, and buried waterproofing (section) lines; existing, new type 1, new type 2, repair, and by-others expansion joint lines; and a work item tag with its quantity and unit, floor, overhead, and vertical repair tags, a coating area tag, and an existing joint tag. Revu's own Legend feature builds a legend from the markups on a page, listed by subject; because each tool's subject is its name, a legend made from these tools reads in the tool names.\u003c\/p\u003e\n\u003cp\u003eExamples of tools included:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Markers (141 tools)\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eSystem tag, work item tag, floor, overhead, and vertical repair tags, coating area tag, existing joint tag, and tags for sheet, liquid-applied, self-adhered, pre-applied, hot-applied, and single-ply membranes, mastic asphalt, cavity drain membrane, wet-area membrane, protection board, and drainage composite\u003c\/li\u003e\n      \u003cli\u003eLaps, terminations, and upstands: shingle lap direction, side and end laps, termination bar, reglet \/ chase, counterflashing, upstand height, corner reinforcing strip, system transition, and limit of waterproofing\u003c\/li\u003e\n      \u003cli\u003eWaterstops and injection: waterstop at construction joint, centre-bulb and external rear-guard waterstops, hydrophilic strip, injection hose, injection port \/ packer, and expansion and control joint markers\u003c\/li\u003e\n      \u003cli\u003eDrainage and penetrations: channel flow arrow, sump chambers with one or two pumps, pump control panel and battery back-up, high-level alarm, flushing point, channel inspection port, rodding eye, inspection chamber, floor gully, two-stage drain, overflow outlet, discharge point, non-return valve, puddle flange and penetration collar markers, service entry, penetration tag, and fall arrows as a ratio or a percent\u003c\/li\u003e\n      \u003cli\u003e27 line tools for membranes, vapour control layer, gas membrane, root barrier, protection board, drainage composite, geotextile, cavity drain membrane, drainage channel, land drain, discharge pipe, laps, waterstop, hydrophilic strip, injection hose, termination bar, membrane terminations (horizontal, and vertical types A and B), upstand, coating extent, and waterproofing extent, 11 of them with a Length tool\u003c\/li\u003e\n      \u003cli\u003e22 area hatches as Polygon and Area tools: sheet, liquid-applied, and cavity drain membrane, drainage composite, protection board, wet area waterproof (WP) and water-resistant (WR) zones, and the legend-style system, scope, traffic coating, existing coating, and existing membrane (to remain, to be removed) areas\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTanking \u0026amp; Below-Grade (52 tools)\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eType A barrier, Type B structurally integral, and Type C drained protection tags, and the combinations A + B, A + C, and B + C\u003c\/li\u003e\n      \u003cli\u003eGrade 1a, 1b, 2, and 3 environment tags and zone hatches, with a grade zone boundary line\u003c\/li\u003e\n      \u003cli\u003eDesign water table, highest water table, perched water, hydrostatic head, hydrostatic pressure diagram, and retained height markers; positive-side, negative-side, and blind-side application markers\u003c\/li\u003e\n      \u003cli\u003eCementitious tanking, crystalline slurry, render tanking, bentonite, and anti-lime treatment notes, tanking height above ground, wall \/ floor junction fillet, and ground gas membrane tag\u003c\/li\u003e\n      \u003cli\u003eCementitious tanking, crystalline slurry, bentonite, render tanking, buried waterproofing (section), and design water table lines; cementitious tanking, crystalline treatment, bentonite, anti-lime treatment, and ground gas protection areas\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDamp-Proofing (50 tools)\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eDPC level and DPC height above ground markers, DPM marker, bridged DPC marker, cavity tray in section and over an opening, weep hole, stop end, and air brick \/ sub-floor vent\u003c\/li\u003e\n      \u003cli\u003eSurvey readings: moisture reading (% WME), moisture profile, meter grid point, hygrometer reading (RH and dew point), rising damp height, tide mark height, salt sample point, and drilled sample point (MC \/ HMC)\u003c\/li\u003e\n      \u003cli\u003eDamp cause tags for rising damp, penetrating damp, condensation, and hygroscopic salts; notes for existing DPC, new chemical and physical DPC, remove plaster, replaster with salt-resistant render, sub-floor ventilation, and lower external ground level; injection point and injection hole row\u003c\/li\u003e\n      \u003cli\u003eDPC, DPM, cavity tray, chemical DPC injection, tide mark, damp extent, and bridged DPC lines (DPC, cavity tray, and chemical DPC injection also as Length tools); damp, rising damp, salt contamination, replaster, and condensation areas\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSealants \u0026amp; Joints (61 tools)\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eSealant joint tag (W x D), sealant type tag, sealant designation tag (type, grade, class, use), sealant class tags 25LM, 25HM, 20LM, 20HM, 12.5E, 12.5P, and 7.5P, and movement class tags 12.5, 25, 35, 50, and 100\/50\u003c\/li\u003e\n      \u003cli\u003eJoint type tags for movement, control, construction, perimeter, isolation, and sanitary joints; backer rod size and bond breaker tape tags\u003c\/li\u003e\n      \u003cli\u003eJoint sections: butt joint 1:1 and 2:1, fillet, lap, bridge, joint with bond breaker tape, preformed compression seal, and hydrophilic bead; remove and replace, tool sealant, primer required, and sealant material notes\u003c\/li\u003e\n      \u003cli\u003e14 joint lines, 12 with a Length tool: sealant joint, expansion joint, existing expansion joint (to remain), new expansion joint type 1 and type 2, expansion joint repair, expansion joint by others, control, construction, and isolation joints, perimeter sealant, joint to remove and replace, crack, and crack injection\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInspection \u0026amp; Testing (82 tools)\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003e17 stamps with editable date, name, and reference fields: hold point, witness point, preparatory, initial, and follow-up inspection, ready for inspection, pass, fail, accepted, rejected, rework required, repaired, re-tested pass, cover-up approved, do not cover, non-conformance, and commissioned\u003c\/li\u003e\n      \u003cli\u003eTest markers for flood test, ELD (low and high voltage), pull-off adhesion, sealant pull, peel adhesion, substrate moisture, wet and dry film thickness, water spray, drainage flow, core sample, and visual inspection, each with fields to fill in, such as the reading, result, date, and tester\u003c\/li\u003e\n      \u003cli\u003eELD breach found and repaired, leak location, water ingress, seepage, damp patch, and photo point; 21 numbered defect marks from pinholes, blisters, and fishmouths to sealant split, ponding, and unsealed penetrations, with a numbered defect tag and a defect closed tag\u003c\/li\u003e\n      \u003cli\u003eFlood test, ELD test, untested margin, retest, spray test, and leak path lines; flood test, ELD tested, untested, defect \/ repair, ponding, leak \/ water ingress, delamination, and spall areas\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBelow-Grade Details (18 details)\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eType A: external sheet membrane to RC wall and slab, internal cementitious tanking to masonry, and pre-applied membrane to secant pile wall and slab\u003c\/li\u003e\n      \u003cli\u003eType B: wall construction joint with centre-bulb waterstop, kicker joint with hydrophilic strip and injection hose, and crystalline wall \/ slab joint with keyway and dry-pack\u003c\/li\u003e\n      \u003cli\u003eType C: wall \/ floor junction with perimeter channel, sump and pump chamber with dual pumps, and existing masonry wall with dry lining; Type A + C external liquid membrane with internal cavity drain\u003c\/li\u003e\n      \u003cli\u003ePipe penetrations with a puddle flange and through a membrane with a collar, slab expansion joint with rear-guard waterstop, membrane termination at ground level, bentonite geocomposite at footing and wall, lift pit, gas membrane under slab, and footing land drain\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWet Area \u0026amp; Deck Details (20 details)\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eShowers and baths: shower wall \/ floor junction, shower floor waste, level threshold shower, shower hob, stepdown shower, bath upstand and sealant, and tap or mixer penetration in a wet wall\u003c\/li\u003e\n      \u003cli\u003eBalconies and decks: balcony door threshold with sill tray, balcony edge drip and termination, deck outlet with two-stage drain, planter box, podium pavers on pedestals, parapet upstand, and deck expansion joint\u003c\/li\u003e\n      \u003cli\u003eWalls and joints: window sill pan flashing with end dams, sealant joint with backer rod and bond breaker, cavity tray over an opening, DPC at wall base lapped to DPM, chemical DPC injection to an existing wall, and internal corner fillet with reinforcing fabric\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 61 line styles and 44 hatch patterns are also included as a line style set and a hatch pattern set for any other markup.\u003c\/p\u003e\n\u003cp\u003eDelivered as a Bluebeam Revu profile that loads all 7 tool sets, the line style set, and the hatch pattern set in one import, plus the individual tool set, line style, and hatch pattern files, in black and redline.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eImport the profile (Revu \u0026gt; Profiles \u0026gt; Manage Profiles \u0026gt; Import, or double-click the .bpx file): one profile for black, one for redline. Or import single tool sets from the Tool Chest (Manage Tool Sets \u0026gt; Import).\u003c\/li\u003e\n  \u003cli\u003eSymbols, tags, notes, and stamps: click a tool, then click the sheet; double-click a text to type over a code, value, date, or name.\u003c\/li\u003e\n  \u003cli\u003eLine tools: click a tool, then click from point to point and double-click to finish. Studs, ribs, hachures, and lettering sit on the right-hand side of the drawing direction or on the line; draw the other way to flip them. Flow arrows point the way the line is drawn.\u003c\/li\u003e\n  \u003cli\u003eArea tools: click a tool, click around the area, and double-click to finish.\u003c\/li\u003e\n  \u003cli\u003eLength and Area tools: draw them like the line and area tools; they measure the length or area drawn.\u003c\/li\u003e\n  \u003cli\u003eDetails: click a detail, then click the sheet; type the detail number and sheet reference into the bubble and edit the notes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently asked questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhich version of Revu do I need?\u003c\/strong\u003e The tool sets were made and checked in Bluebeam Revu 21.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAre the details editable?\u003c\/strong\u003e The notes, leaders, title, and detail bubble are native Bluebeam markups, and every text is editable. The material hatching is a vector snapshot inside the detail: it moves and resizes with the detail but is not edited line by line.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMetric or imperial?\u003c\/strong\u003e Detail notes give millimetres with inches in brackets. The work item tag takes any unit (m2, SF, m, LF, EA).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDo the tools name products or manufacturers?\u003c\/strong\u003e No. Tags, notes, and details describe generic systems; type the specified product or system code over them.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCan Revu make a legend from these tools?\u003c\/strong\u003e Revu's Legend feature lists the markups on a page by subject. Each tool's subject is its name, so the legend uses the tool names.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWhat is in the download?\u003c\/strong\u003e One zip file with both editions. Each edition has a profile (.bpx), the 7 tool set files (.btx), the line style set (.blx), and the hatch pattern set (.bhx).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MarkupToolSets","offers":[{"title":"1 Device","offer_id":68236926419240,"sku":null,"price":97.49,"currency_code":"USD","in_stock":true},{"title":"2-5 Devices","offer_id":68236927762728,"sku":null,"price":191.24,"currency_code":"USD","in_stock":true},{"title":"Unlimited Devices (Incl. Support \u0026 Free Updates)","offer_id":68236927795496,"sku":null,"price":303.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0910\/6345\/1944\/files\/001-waterproofing-membrane-tanking-sealant-inspection-symbols-bluebeam-markup-tool-set.png?v=1795068738","url":"https:\/\/markuptoolsets.com\/products\/waterproofing-bluebeam-tool-set","provider":"MarkupToolSets","version":"1.0","type":"link"}